What this online decibel meter measures — and what it can't
This decibel meter measures how loud the sound reaching your microphone is, relative to the loudest level your device can capture. That number is dBFS (decibels relative to full scale), where 0 dBFS is clipping and everything else is negative. It is reliable for comparisons — this room against that room, the fan on against the fan off, today against yesterday — as long as you use the same device and settings.
What a browser cannot do on its own is report true sound pressure in dB SPL, the number a dedicated sound level meter shows. Converting dBFS to dB SPL needs the microphone's sensitivity and the exact input gain, and no browser exposes those as trusted values. That is why this page offers an optional one-point calibration: give it one reading from a reference meter and it shows an estimated dB from then on. The estimate is unweighted, valid only for that microphone, gain and browser, and it is not a certified or hearing-safety measurement. Most online decibel meters show a dB number without saying any of this; we would rather you know what the number means.
How to measure how loud your room is, step by step
- Press Start measuring. The browser asks for microphone permission only after you click. The page requests the microphone with echo cancellation, noise suppression and automatic gain control turned off, so quiet and loud sounds are not squeezed toward the same level.
- Hold the device still and point the microphone at the room.Keep it about arm's length from your body, away from walls and off soft surfaces that muffle it. Do not cover the microphone opening.
- Read the current level and the Min / Avg / Max boxes. The large number moves with the sound; Min, Avg and Max summarize the last several seconds. Max turns red at −12 dBFS or above, which means you are close to clipping.
- Compare, or calibrate. Use the relative scale below the waveform for a rough sense of level, from −75 dBFS (very quiet input) to −15 dBFS (near clipping), or calibrate as described below to read estimated dB.
If the number never moves or the waveform stays flat, check the microphone itself with the online mic test first, and work through the microphone not working fixes if no level shows at all.
dB vs dBFS: why the meter starts at a negative number
dB SPL and dBFS use the same logarithmic unit but different reference points. dB SPL is measured upward from 20 micropascals, roughly the quietest sound a young listener can hear, so a quiet room is about 30 dB SPL and a loud concert is over 100. dBFS is measured downward from the digital ceiling of the recording path, so every real reading is negative and a louder sound moves the number toward 0.
The two scales move together: if the room gets 10 dB louder, the dBFS reading also rises by about 10 dB, as long as the signal stays above the noise floor and below clipping. What differs from device to device is the gap between them. The same conversation might read −45 dBFS on one laptop and −25 dBFS on another, and neither is wrong. That fixed gap is exactly what a calibration measures.
How to calibrate this decibel meter against a reference
One-point calibration means measuring one steady sound with both a trusted meter and this page, then storing the difference. The page adds that offset to every later dBFS reading. Here is the procedure that matches the tool:
- Borrow a sound level meter, or use a meter app on a device that has itself been calibrated. Set it to Z or C weighting if it offers them; otherwise A is acceptable with a 1 kHz tone.
- Play a steady sound at a comfortable, moderate level. A 1 kHz sine from the online tone generatorworks well on a second device, because A, C and Z weighting all read the same at 1 kHz, so the reference's weighting no longer matters.
- Place the reference meter's microphone right next to your device's microphone, both facing the source from the same distance. Even 30 cm of difference changes the reading in a small room.
- Press Start measuring, type the reference reading into the calibration box, and press Set calibration while the same sound is still playing. The page captures the level at that moment.
- The readout switches to an estimate such as
≈62 dB, with the raw dBFS and the offset shown underneath. The offset is remembered in this browser; press Clear to remove it.
Recalibrate whenever anything in the chain changes: a different microphone or headset, a new input volume in your system settings, another browser, or an operating-system update that changes audio processing.
Why one-point calibration drifts at the extremes
A single offset assumes the microphone responds in a straight line at every level and frequency, which is only true in the middle of its range. In a very quiet room, the reading bottoms out at the combined noise of the room, the microphone and its electronics, so the meter cannot show anything quieter and low readings come out too high. At very high levels the microphone or its preamp starts to compress and then clips at 0 dBFS, so loud sources read too low. Frequency matters too: a laptop microphone that was calibrated at 1 kHz may under-read a bass-heavy subwoofer or a high-pitched alarm. Expect the best results within a few tens of dB of the level you calibrated at, with a sound similar in character.
Typical noise levels: how loud is your environment?
These are approximate, A-weighted, typical values in dB SPL for familiar sources at ordinary listening distances. Real measurements vary with distance, room and equipment, so treat them as orders of magnitude rather than targets.
| Source or setting | Approx. dB(A) |
|---|---|
| Threshold of hearing | 0 |
| Rustling leaves, soft whisper | 20–30 |
| Quiet bedroom at night | 25–35 |
| Library, quiet office, refrigerator hum | 35–45 |
| Normal conversation at about 1 m | 55–65 |
| Busy restaurant, open-plan office | 65–75 |
| Vacuum cleaner, busy street traffic | 70–85 |
| Lawn mower, blender, subway train | 85–100 |
| Rock concert or nightclub near the speakers | 100–110 |
| Siren at close range, threshold of pain | 120–130 |
A useful sanity check after calibration: a quiet room should land in the 30s or 40s, and normal speech at arm's length in the 50s or 60s. If your estimate is far outside those ranges, the calibration was probably taken with the devices at different distances.
dB(A), dB(C) and dB(Z): what frequency weighting means
Frequency weighting is a filter a sound level meter applies before it calculates the level, and it explains why two meters can disagree about the same noise.
- A-weighting, dB(A), strongly discounts low frequencies and slightly discounts very high ones, approximating how the ear responds to moderate sounds. It is the standard for environmental noise, workplace exposure and most published limits.
- C-weighting, dB(C), is nearly flat across the audible range and only rolls off at the extremes. It keeps bass, so it is used for loud music, low-frequency complaints and peak levels.
- Z-weighting, dB(Z), means zero weighting: a flat measurement over the meter's range.
All three are defined to read the same at 1 kHz. The difference appears with bass: a booming car stereo or an HVAC rumble can read 10 dB or more higher in dB(C) than in dB(A). This page does not apply a weighting filter, so its calibrated estimate behaves closer to dB(Z), limited by whatever your microphone actually picks up, and it will read higher than a dB(A) meter on bass-heavy sounds.
How decibels add up: the logarithmic scale and distance
Decibels are logarithmic, so small differences in the number are large differences in energy.
- +3 dB is double the sound power. Two identical, unrelated noise sources, such as two fans, are about 3 dB louder than one, not twice the number.
- +6 dB is double the sound pressure.
- +10 dB is ten times the sound power and is perceived as roughly twice as loud. A 70 dB street sounds about twice as loud as a 60 dB conversation.
Distance matters just as much. Outdoors, away from reflecting surfaces, the level from a small source falls by about 6 dB every time you double the distance: a machine that reads 90 dB at 1 m reads about 84 dB at 2 m and 78 dB at 4 m. Indoors, reflections from walls and ceilings keep the level higher than that rule predicts once you are a few meters from the source. When you compare readings, write down the distance and keep it the same.
Is a phone or laptop mic accurate enough for a sound level meter?
A phone or laptop microphone is accurate enough to compare levels and, after calibration, to estimate everyday noise within a few decibels near the calibration point. It is not accurate enough for compliance or health decisions, for five reasons:
- Automatic gain control and noise suppression. Built for calls, they raise quiet input and remove steady noise, which flattens exactly the differences a meter needs. This page asks the browser to turn them off, but some devices and drivers apply processing anyway.
- Frequency response. Small built-in microphones are tuned for speech and often roll off deep bass, so low-frequency noise reads lower than it is.
- Limited range at both ends. Their noise floor hides very quiet rooms, and loud sources such as concerts can overload the microphone or clip the input.
- Distance and angle. Phone and laptop microphones sit behind small ports and are partly directional; turning the device or holding it near your body changes the reading.
- Input gain. Changing the system input volume shifts every reading by the same amount and silently invalidates a calibration.
When you need a real sound level meter
Use a proper sound level meter whenever a number has consequences. International standard IEC 61672-1 defines Class 1 (precision) and Class 2 (general purpose) sound level meters with specified tolerances, and noise ordinances, workplace assessments and legal disputes generally expect one of them, often used by a local authority or acoustic consultant.
- Noise complaints. A browser meter is useful for a personal log of when noise happens and how far it rises above your normal background. Contact your local authority for an official measurement.
- Workplace noise. Occupational guidance commonly treats prolonged exposure above about 85 dB(A), averaged over a working day, as the level where hearing risk begins. Exposure assessments use calibrated meters or personal noise dosimeters.
- Hearing and health. This page is not a medical or hearing-safety tool. If loud environments leave your ears ringing or muffled, take it to a hearing professional.
Method and related tests
The meter computes the RMS level of short blocks of the live microphone signal through the browser's Web Audio interface and displays it in dBFS; the calibrated estimate is that dBFS value plus your stored offset. Nothing is recorded or uploaded. The full method and known limits are on how we test. To play a steady reference signal for calibration, use the tone generator; to confirm the input before measuring, run the microphone test.